Protecting EV integrity from isolation to downstream analysis
EVs are dynamic biological nanoparticles; the physical and biological properties of EVs can change during handling and storage. Freeze-thaw cycles, prolonged incubation, buffer composition and sample handling may all influence EV integrity, potentially affecting downstream analytical and functional studies.
Careful sample preservation is therefore essential for maintaining reproducible EV measurements and ensuring experimental results reflect biological differences rather than sample degradation.
Why is EV preservation important?
EVs are commonly isolated several hours (or even days) before downstream analysis.
During this time, changes to the sample may influence:
- Particle concentration
- EV membrane integrity
- Aggregation
- Fluorescence stability
- RNA quality
- Protein stability
- Biological activity
Maintaining EV stability throughout the workflow helps improve reproducibility and confidence in downstream analyses.
How should EVs be stored?
Storage | Recommendation |
Immediate Use | Keep on ice / 4°C |
Short-term | 4°C |
Long-term | -80°C |
Freeze-thaw | Minimise |
Why use a dedicated EV preservation buffer?
An effective preservation buffer should:
- Maintain osmotic balance
- Reduce EV aggregation
- Preserve EV integrity to support reliable downstream analysis
Comparing performance of PBS with Vesi-Safe EV preservation buffer
Figure 1. Vesi-Safe substantially improves EV preservation following dilution compared with PBS. A) Schematic of the experimental workflow. Vesi-Ref CD63-mNG EVs (Vesiculab) were diluted in either PBS or Vesi-Safe EV preservation buffer and analysed by imaging flow cytometry (CellStream) 30 min and 24 h after dilution. B) Representative scatter plots showing the mNG-positive (mNG+) population following dilution to 1E+06 particles/mL. Substantially fewer mNG+ events were detected following dilution in PBS compared with Vesi-Safe. C) Quantification of mNG+ events following dilution to 1E+06 or 1E+07 particles/mL. At 30 min, PBS resulted in 69% and 47% fewer detectable mNG+ events than Vesi-Safe at 1E+06 and 1E+07 particles/mL, respectively. After 24 h, this difference increased to 91% and 86%, demonstrating improved preservation of detectable EVs in Vesi-Safe following dilution.
Practical tips for handling and storing EV samples
- Aliquot samples before freezing
- Minimise freeze-thaw cycles
- Store at appropriate temperatures (4°C short-term, -80°C long-term)
- Use low protein-binding plastics
FAQs
Can EVs be stored in PBS?
PBS is commonly used for EV storage, but it is not specifically designed to preserve extracellular vesicles (EVs). EV loss can occur during storage and following dilution, particularly at low particle concentrations. Vesi-Safe is an EV preservation buffer designed to improve EV stability and recovery compared with PBS.
Why are EVs lost during dilution and storage?
EVs can adsorb to plastic tubes and other laboratory surfaces during routine handling. This can be particularly problematic when working with dilute samples, where surface adsorption can result in the loss of a substantial proportion of available EVs. Vesi-Safe is formulated to minimise surface-associated EV loss and improve EV recovery during dilution, handling and storage.
What temperature should EVs be stored at?
For long-term storage, EV samples are generally stored frozen, typically at −80°C. For short-term handling, samples may be kept refrigerated or on ice depending on the application. Vesi-Safe is designed to help preserve EVs during storage and handling, including conditions where sample loss can otherwise occur.
Can Vesi-Safe be used with fluorescently labelled EVs?
Yes. Vesi-Safe can be used with fluorescent EV samples and is particularly useful where EVs need to be diluted to low concentrations for fluorescence-based analysis. In our testing, fluorescent Vesi-Ref CD63-mNG particles diluted in Vesi-Safe retained substantially more detectable mNG-positive events than particles diluted in PBS.
Is Vesi-Safe suitable for plasma-derived EVs?
Vesi-Safe can be used to resuspend and preserve EVs isolated from plasma. As Vesi-Safe is a preservation buffer rather than an isolation reagent, plasma components should first be removed using an appropriate EV isolation or purification method, such as Vesiculab’s all-in-one plasma EV isolation kit, Vesi-Omics.
Can Vesi-Safe protect EVs during freeze–thaw?
Vesi-Safe is designed to help preserve EVs during frozen storage and freeze–thaw. However, repeated freeze–thaw cycles should still be minimised, and aliquoting samples before storage is recommended.
Can Vesi-Safe be used when diluting EV samples?
Yes. Vesi-Safe can be used as a diluent as well as a storage buffer and is particularly useful when EVs need to be diluted to low particle concentrations. In our testing, substantially more fluorescent EVs remained detectable after dilution in Vesi-Safe than in PBS, with the difference becoming greater over time (Figure 1).
Why use an EV preservation buffer instead of PBS?
PBS provides an isotonic environment but is not specifically formulated to preserve EVs. EVs can be lost during storage, handling and dilution, particularly at low concentrations. Vesi-Safe is formulated specifically for EV preservation, helping maintain EV recovery under conditions where substantial losses can occur in PBS.